Special Cables
Trailing cables Cables for renewable energy Single Conductor Airport 400Hz Truck cables more

Trailing CableTW1/ TW2/ TW3

Application

TW1: Here the cable is drawn vertically from a drum as a drag cable via the load platform. The load platform

pulls the cable along as it moves up. During the downwards motion the cable returns to the drum automatically.

Our special versions are used at heights of up to about 150 meter.

TW2: For greater heights, a so-called carriage version is employed, in which the cable is fed at the center of the

tower, i.e. half the way up.

TW3: Here the cable is guided via a spring-loaded drum. These vertical construction lifts are used during new

construction and renovation work on high buildings. The rack lattice elements are fastened at intervals to the

exterior facade.

Temperature range

flexing -10°C to +80°C

Nominal voltage

control conductors 300/500 V,power supply conductors 0,6/1 kV

A.C. test voltage, 50 Hz

control conductors 1500 V,power supply conductors 3000 V

Minimum bending radius

approx. 10x cable diameters

Properties

Jacket UV-resistant;

In carriage version with special support braiding and with PUR jacket particularly resistant to wear, oil, hydrolysis

andmicrobial attack.

Trailing CableTW1

Description & No. Conductors x crosssec.mm² Outer Diameter Copper weight kg/km Weight ca. kg/km
TW1 5x2.5 + 10x1.0 20.0 220.0 306.0
TW1 5x2.5 + 11x1.0 20.0 225.6 320.0
TW1 3x4.0 + 7x1.0 17.4 184.0 360.0
TW1 4x6.0 + 9x1.0 20.5 330.0 555.0
TW1 4x6.0 + 10x1.0 21.0 340.0 575.0
TW1 4x6.0 + 15x1.0 22.0 388.0 625.0
TW1 4x10.0 + 10x1.0 25.0 480.0 870.0
TW1 4x16.0 + 6x1.0 26.1 700.0 1250.0
TW1 4x16.0 + 10x1.0 29.0 710.0 1300.0
TW1 4x16.0 + 15x1.0 31.5 760.0 1380.0
TW1 4x16.0 + 1x2.5 + 4x1.0 28.5 830.0 1460.0

Trailing CableTW2

Description & No. Conductors x cross-sec. mm² Outer Diameter Copper weight kg/km Weight ca. kg/km
TW2 4x16.0 + 1x2.5 + 2x2x1.0 28.5 830.0 1080.0
TW2 4x16.0 + 1x2.5 + 2x2x1.0 28.5 830.0 1080.0
TW2 4x25.0 + 1x2.5 + 2x2x1.0 33.4 1176.0 1500.0
TW2 4x35.0 + 4x2.5 + 2x2x1.0 + 1x1.0 38.0 1500.0 1850.0

Trailing CableTW3

Description & No. Conductors x cross-sec. mm² Outer Diameter Copper weight kg/km Weight ca. kg/km
TW3 4x2.5 + 3x1.0 13.0 125.0 230.0
TW3 4x2.5 + 3x1.0 15.3 125.0 280.0